Instrument Devices Supply, Installation, Calibration/Services and Commissioning such as:

1.) Pressure Transmitter
2.) Pressure Switch
3.) Flow Transmitter method type :
• Flow Transmitter
• Turbine Flow Meter
• Mass Flow Meter –Coriolis/Liquid
• Ultrasonic Flow Meter
• Vortex Flow Meter
4.) Flow Switch
5.) Temperature Transmitter
6.) Temperature Switch
7.) Level Switch
8.) Level Transmitter method type :
• Guide wave radar
• Radar
• Magnetic Level Transmitter with Level gauges
• Level Differential pressure Transmitter
• Ultrasonic Level Transmitter
9.) Beacon Lighting FGS System :

• Beacon Lighting Cooper type, glass type
• MEDC spec and various lens colors
• Zone 1 and Zone 2 use
• Exd IIC T4/T5/T6 and SIL Certified
• IECEx Certified Gb, Db.
• ATEX approved, Ex II 2GD.
• IP66 & 67 & Certified temperature -55°C to +70°C
• Pipe mount or direct mount enclosure
• Four wires and supervisory diode

10.) Combustible Gas Detector Point Type and Gas Detector Open Path FGS System :

• Two independently and field selectable alarm threshold levels for each channel
• Two latching ( normally open/ normally closed) Alarm relays for each channel
• Digital displays indicate the level of gas being detected
• Current output feature (4 to 20 mA) allows monitoring of gas concentration through external remote devices
• Front panel accessibility for calibration adjustments
• Operating voltage 24 VDC nominal with a 20 to 35 VDC range (standard), 120 or 240 VAC, +10%, -15% (optional)
• Controller outputs –normally open/normally closed relay contact are rated 3 amperes at 24 VDC or 120/240 VAC
• Transmitter and Receiver for open path gas detector

11.) Manual Alarm Call Point/ESD Push Button for Safety System

• Addressable manual call point for fire alarm or an extinguishing process- Indoor and outdoor application
• Available colors Red, Yellow, Green and Blue
• Direct alarm actuation by pushing in the glass plate
• Exd, Exia (Intrinsically Safe) with weatherproof

12.) Addressable Smoke Detector and Heat Detector for FGS System

• Addressable smoke detector for fire alarm or an extinguishing process- Indoor and outdoor application
• Light Source-GaAIAs Infrared Emitting Diod
• Rated Voltage 17.7-30.0 VDC and Working Voltage 15.0 – 33.0 VDC
• Surge Current and Alarm Current 24 VDC
• Ambient Temperature 32°F to 120 F ( 0° C to 49°C ) –smoke detector
• Sensitivity Test Feature –Automatic sensitivity window verification test

• Heat detector for fire alarm or an extinguishing process- Indoor and outdoor application
• Operating voltage 17-41 VDC
• Current consumption standby -Normal 390µA (typical)
• DCP –Digital communication protocol
• UL Ambient installation temperature range -32°F to 100°F ( 0°C to 37.8°C )
• Operating temperature range -14°F to 122°F ( -10°C 50° C )
• Sensitivity range 300FPM,2000FPM,4000FPM
• Air velocity range 0 – 4000fpm and weight 3.4oz (5.1 oz. with 4” base)
13.) UV/IR Flame Detector for Fire and Gas Safety System
• Wire field of view for greater fire detection coverage
• 4 to 20 mA stepped output is the industry standard for remote alarm and fault indication
• EExe wiring compartment meets high reliability requirements and provides ease of field wiring connection
• Wide operating temperature range permits operation at higher ambient temperature
• Continuous Optical Path Monitoring (COPM) checks optical path integrity and detectors electronic circuity once every minute
• Three SPDT high current programmable relay outputs provide immediate and time delayed relay outputs for alarm, programmable relay outputs
14.) Sand Probe for instrument safety system

• Probe length – adapter to pipe size
• Element thickness – 30-1000µm, depending on expected corrosion rate (typical thickness is 50, 100 or 150 micron)
• Probe connection 1/8” – ½” NPT with RTJ flange

15.) High Low Pilot for Instrument Safety System

• Complete range of pressure settings within a compact package
• Standard type 316 SS components material
• Normally open and Normally closed
• Set pressure 0.5 psi to 10,000 psi
• ¼ FNPT control port
• Dead band +/- 10% of set pressure

16.) Versa Pilot Valve, Manual Shu-Off Valve and Pneumatic Relay Controller
• Three-Way (3/2) manual/pilot operated main supply reset valves and three-way (3/2) indicating relay valves.
• All constructed of 316 stainless steel (meets NACE standard MR-01-75)
17.) Pressure Gauges, Level Gauges and Temperature Gauges